HP — 4.0 Non-Code Errors

-113 5. Excess Material Inside Head - Filament Buckled / Spaghetti Head - Encased Head 1. Check for loose heater block clamp screws. 2. Make sure the head connectors are seated properly. 3. Check air plenum for: proper hose connection; properly seating; cracks or damage. 4. Check to make sure head blower fan hose is connected to blower. 5. If extrusion fails on first layer with a used modeling base, retry with a new one 6. Rerun Z calibration 7. Plugged Liquefier - replace tips. 8. Inspect model for excessive overfill. a. Toolpaths should not overlap by more than 50%. If so, reorient and reprocess STL. b.

If model curl has caused the part to contact the tip, reprocess part with less dense fill. Re-run tip Z cal if part is separating from supports c. If part curl continues, see part curl section 9. Check idler wheel gap. 10. Check liquefier alignment. 11. Head idler spring is deformed or installed improperly. Replace head idler spring. 12. Possible head temperature issue a. Replace head board and TC Amp board. b. Replace toggle head assembly. 13. Head motor power wires or encoder failure - replace toggle head 14. Blower fan not supplying enough air flow - weak or stalling. Replace fan. 15. Replace umbilical cable 16. Replace controller board 17. In case of Z shift: a. Realign Z guide rods. b.

Replace Z motor and leadscrew. c. Replace Z assembly. 6. Filament motor is running very fast. 1. Make sure the head connectors are seated properly. 2. Bad motor. Replace toggle head assembly. 3. Broken wire in the umbilical cable. Replace umbilical cable.