-124 N. "Can't Find Home - Check Modeling Base" displayed on LCD 1. Head stops over Z stage/ modeling base 1. No modeling base 2. Modeling base is used/defective - Replace 3. Verify substrate sensor is working properly, verify at LED/test points on PDB. 4. Substrate sensor is loose or defective, tighten or replace. 2. Head moves to lower modeling base sensor but does NOT move over modeling base 1. Modeling base sensor is NOT turning off before performing touchdown (verify using LED) 2. Y EOT sensor is not operating correctly. Verify using LED/test points on PDB. 3. Debris on Z Stage casting prevents Z stage from finding home 3.

Head completes finding modeling base routine then displays error message. 1. Modeling base is used/defective - Replace 2. Z offset value is incorrect (out of operating range) Check/adjust value using HP Designjet 3D Diagnostic Software. 3. Flatness check may have failed. Use Tera Term to read the touchdown values. Compare these values to the "tolerance" value displayed. If this value is over 1728 replace the modeling base. 4. If failure reoccurs check XY table level using the head bracket and dial indicator. Values should be a band of 0.010 total for the four points (0.003 total) - If values are out of spec: Check for loose tray mounting screws. If so level per procedure.

- If screws are tight, level the XY table per procedure. 5. If failure reoccurs the X rear guide rod may be out of alignment. Replace XY table. 4. Head stops moving while attempting to lower Z detect sensor plunger 1. Using PDB LED's check to see that all sensors are working correctly. If not check sensor connections/wires or replace sensor 2. Z offset value is incorrect (out of operating range) Check/adjust value using HP Designjet 3D Diagnostic Software.