HP — Installing the toggle head assembly

viii.When finished, press Done... ix. Press the Next... button until you reach the last page. x. Press the Done... button. xi. Press the Save and reboot button. B. For printer firmware version 9.0 or older: i. The printer will reboot and return to idle. Load the HP Designjet 3D Diagnostics Software. ii. Click on the + button to add the printer. iii.Enter the printer name, printer type, printer location and printer IP address. iv. Click on the green check mark button. v. Connect to the printer in HP Designjet 3D Diagnostics Software by selecting it out of the Current Modeler drop down menu. vi. Click on the Tip Offset button.

vii.Enter the value from Z Tip to Tip field on the tag that came with the toggle head assembly into the Z Tip to Tip field in the Tip Offset window. viii.Click on the green check mark button. ix. Cycle power to the printer. x. From the display panel press Maintenance > Machine > Tips xi. Perform Z calibration. xii.Perform XY Offset calibration. -219