Installing the umbilical hose 1. Feed the umbilical hose through the energy chain. 2. Align the energy chain with the mounting holes. 3. Using a 5 ⁄ 32 ” allen wrench, reinstall the energy chain mounting screws. 4. Reinstall a wire tie around the umbilical hose. See Figure 192. Figure 192: Umbilical hose wire tie location Reinstall the wire tie 5. Reconnect the model and support material tubes. 6. Reinstall the air plenum. 7. Reinstall the head cover. 8. Reconnect the umbilical hose to the head cooling fan. 9. Using a 1 ⁄ 4 ” nut driver or standard screwdriver, tighten the umbilical hose clamp. 10. Align the right side access panel with the mounting holes. 11.
Using a 5 ⁄ 16 ” nut driver or standard screwdriver, reinstall the right side access panel mounting screws. 12. Reinstall the upper electronics bay cover. See “Installing the upper elec- tronics bay cover” on page 174 13. Reinstall the side panels. See “Installing the side panels” on page 164 14. Reinstall the top panel. See “Installing the top panel” on page 162 -245