HP — Installing the XY table

6. The gauge should read between 0.425 and 0.435 mils. See Figure 263. Figure 263: Gauge readings Service Limit Adjustment Limit 7. If the tension is not within specification, locate the Y belt tension adjust- ment nut on the front of the system. See Figure 262. 8. Adjust (increase/decrease) the tension by turning the tensioning nut ( Fig- ure 264. ) so that the dial indicator reads between 0.425 and 0.435 mils. Figure 264: Y drive belt tension adjustment Y-Drive Belt Tension Adjusting Nut 9. Remove the belt fixture and move the belt forward and back several times. 10. Reattach the belt tension gauge and recheck the tension. 11.

Continue to adjust and check the tension until the tension meets specifi- cation. -292