HP — Performing part based calibration for HP Designjet 3D from the Service Calibration menu (Firmware version 9.1 or newer)

31. Press the GRight button. Enter the value recorded from step 17 by press- ing the Increment , Decrement and Next Digit buttons. 32. When finished, press Done... 33. Press the GFront button. Enter the value recorded from step 12 by press- ing the Increment , Decrement and Next Digit buttons. 35. Press the Next... button. 34. When finished, press Done... 36. Press the GRear button. Enter the value recorded from step 16 by press- ing the Increment , Decrement and Next Digit buttons. 37. When finished, press Done... 38. Press the GLF button. Enter the value recorded from step 26 by pressing the Increment , Decrement and Next Digit buttons. 39. When finished, press Done... 40.

Press the GLR button. Enter the value recorded from step 22 by pressing the Increment , Decrement and Next Digit buttons. 41. When finished, press Done... 42. Press the Next... button until you reach the last page. 43. Press the Done... button. 44. Press the Save and reboot button. 45. The printer will reboot and return to idle. 46. Build a sample part to verify proper operation. -351 NOTE: The value for GRight must be between 5.250” and 5.750”. NOTE: The value for GFront must be between 7.250” and 7.750”. NOTE: The value for GRear must be between 7.250” and 7.750”. NOTE: The value for GLF must be between 9.051” and 9.551”. NOTE: The value for GLR must be between 9.051” and 9.551”.