Performing part based calibration for HP Designjet 3D with the HP Designjet 3D Diagnostic Software 1. Open HP Designjet 3D Diagnostic Software and select the current modeler from the pull down menu. 2. Open Gantry Calibration Dialog box in HP Designjet 3D Diagnostic Software 3. Set the X adjust value to 0. 4. In the Part Calibration section, there are six boxes: LEFT, RIGHT, FRONT, REAR, LEFT FRONT and LEFT REAR. Set these values to 0. 5. Click on the green check mark to save the values. 6. Toggle the system power down switch. 7. Once the system displays Idle, press Maintenance>System>Test Parts then select the test_XY_cal part. 8.
When part is completed, remove from printer and let cool for five min- utes. 9. Locate the filled circle, this indicates the front of the substrate, see Figure 338 Figure 338: Locating the Filled Circle (B) 10. Using a digital caliper, measure and record the diameter of circle B along the center line between A and C, see Figure 339 NOTE: Reference letters are not actually “printed” on the part. If needed, use the Part Measurement Equations sheet to record the values. See “Part Measurement Equations” on page 359. -352