-76 Error message on display panel Recommendation Can’t Find Home – Check Modeling Base 1. Verify a modeling base is inserted. 2. Modeling base may be used or defective – replace. Material Error Filament error 1. Remove the carrier and verify material is coming out of the material guide. 2. Verify material pulls freely from the carrier. 3. Verify the material tubes are free of mate- rial. 4. Reload material. Material Error Filament blocked 1. Remove carrier and verify material pulls freely from carrier. 2. Verify the material tubes are free of mate- rial. 3. If the path is not obstructed, clean debris from Filament Present Switch.
See “Remove debris from the Filament Present switch” on page 64. 4. Reload material. Material Error Carrier invalid 1. Remove carrier and verify it is not empty. 2. Replace material spool. 3. Reload material. Material Error Filament broken 1. Remove the carrier and verify material is coming out of the material guide. 2. Verify material pulls freely from the carrier. 3. Verify the material tubes are free of mate- rial. 4. Reload material. Load Error Filament blocked 1. Remove the carrier and verify material is coming out of the material guide. 2. Verify the material pulls freely from the carrier. 3. Verify the material tubes are free of mate- rial. 4.
If the path is not obstructed, clean debris from Filament Present Switch. See “Remove debris from the Filament Present switch” on page 64. 5. Reload material.