Chapter 7: Maintenance Leave the lower U-joint connected to the platform shaft. WARNING: Do not rotate the drive shaft or the lower U- joint. If either is rotated, the calibration data for J4 will be lost, requiring factory recalibration. Retain the dog point set screw for reassembly. It was installed using Loctite 242. 3. Unscrew the three screws at the lower end of the drive shaft. Retain the screws for reassembly. These hold the end cap that holds a sleeve bushing through which the center shaft slides. 4. Remove and discard the lower end cap from the drive shaft cylinder. It will slide over the center shaft. A new end cap is included in the bushing replacement kit. 5.
Remove the center shaft from the drive shaft cylinder. Retain the center shaft for reassembly. 6. The upper end of the center shaft has a fixture that holds three bushings. These bush- ings will be replaced, but the center shaft will be reused. Figure 7-5. Center Shaft Bushing-holding Fixture, with Bushings 7. Remove and discard the three old bushings from the fixture at the end of the center Hornet 565 Robot User's Guide, 14608-000 Rev C Page 108 of 156