Chapter 7: Maintenance 7.9 Replacing the Encoder Battery Pack The data stored by the encoders is protected by a 3.6 V lithium backup battery pack located in the base of the robot. CAUTION: Replace the battery pack only with a 3.6 V, 6.8 Ah lithium battery pack, P/N 09977-000. Battery Replacement Interval If the robot is kept in storage and not in use, or if the robot is turned off (no 24 VDC supply) most of the time, then the battery pack should be replaced every 5 years. If the robot is turned on, with 24 VDC supplied to the robot more than half the time, then you can increase the replacement interval to 10 years.
If, for example, a robot is typically turned off only on weekends, the battery pack would need to be replaced every 10 years. Battery Replacement Procedure 1. Obtain the replacement battery pack. 2. Switch off the optional SmartController EX, if one is being used. 3. Switch off the 24 VDC input supply to the robot. 4. Switch off the 200-240 VAC input supply to the robot. 5. Disconnect the 24 VDC supply cable from the robot +24 VDC input connector. See Robot Interface Panel on page 46 for locations of connectors. 6. Disconnect the 200-240 VAC supply cable from the robot AC input connector. 7. Switch off and disconnect any other power supplies connected to the robot. 8.
Remove the four M4 hex-head bolts holding the Status Display panel. l Retain the bolts for re-installation. l These bolts were installed with Loctite 222. Hornet 565 Robot User's Guide, 14608-000 Rev C Page 112 of 156