omron — 7.9 Replacing the Encoder Battery Pack

Chapter 7: Maintenance Battery Cable Diag Cable Cable Tie In-use Battery Connector Battery Pack Battery Bracket Unused Battery Connector Status Display Panel Diag Cable Connector Figure 7-9. Battery Bracket on Status Display Panel 12. Once the new battery pack is connected, you can disconnect and remove the old one. You will need to cut the cable tie holding the battery pack in the bracket. NOTE: Dispose of the battery pack in accordance with all local and national envir- onmental regulations regarding electronic components. 13. Place the new battery pack in the battery bracket, and secure it and the “diag” cable, using a cable tie.

l Fold any excess wiring (red and black) under the battery pack, so that it lies between the battery pack and the ‘V’ in the battery bracket. l The “diag” cable must be cable-tied to the bracket (and battery pack) to relieve strain on the Status Display connector. NOTE : In the preceding figure, the diag cable has not yet been attached to the bat- tery bracket. 14. Re-install the Status Display panel with the four M4 bolts previously removed. l Apply Loctite 222 in each bolt hole, not on the bolts themselves. l Ensure that the Status Display panel gasket is in place between the panel and the robot body. l Torque the bolts to 1.1 N·m (10 in-lb).

Hornet 565 Robot User's Guide, 14608-000 Rev C Page 114 of 156