omron — 7.12 Replacing a Platform

Chapter 7: Maintenance You will encounter some resistance, as there are three plug-type connectors that will be disconnected as you pull the front cover away from the body. NOTE: Separate the cover from the body slowly to avoid damaging the two wires that go between the LED and the PC board inside the body. Pull the front cover as straight out as possible. You do not have to disconnect the wires from the PC board, although you can if needed. 7. Locate the lamp body in the center of the back side of the front cover. Turn the lamp body approximately 20° in either direction and then pull straight back. 8. The lamp body is now free. You can remove the old lamp and insert a new one. 9.

Re-install the lamp body by pushing it straight into the lamp housing receptacle. Make sure the contacts on the lamp body are properly oriented, as shown in the following fig- ure. 10. Make sure to reconnect the wires from the LED if you disconnected them earlier. 11. Push the front cover into the body, taking care to align all of the plug-type connectors. Verify that the wires do not get crimped as you reinstall the cover. 12. Re-install the two screws on the back of the body. 13. Re-install the Front Panel in its mounting. 14. Reconnect the cable between the Front Panel and the eAIB (or controller). Back side of front cover Wires between LED and body of Front Panel.

Be careful when separating front cover from body to avoid damaging the wires. High Power On/Off Lamp Body Figure 7-10. Lamp Body Contact Alignment 7.12 Replacing a Platform CAUTION: Do not overstretch the outer-arm springs. Separ- ate the ball joint sockets only enough to fit them over the ball studs. Hornet 565 Robot User's Guide, 14608-000 Rev C Page 116 of 156