omron — Removing the eAIB Chassis

Chapter 7: Maintenance 7.15 Replacing the eAIB Chassis Removing the eAIB Chassis CAUTION: Follow appropriate ESD procedures during the removal/replacement phases. 1. Switch off the 24 VDC input supply to the chassis. 2. Switch off the 200/240 VAC input supply to the chassis. 3. Switch off the optional SmartController EX, if you are using one. 4. Disconnect the 24 VDC supply cable from the chassis +24 VDC input connector. For the connector location, see Robot Interface Panel on page 46. 5. Disconnect the 200/240 VAC supply cable from the chassis AC Input connector. 6. Disconnect the eAIB XSYSTEM cable from the chassis XSYSTEM connector. 7.

Disconnect any other cables, which may be connected to the chassis, such as XIO, RS- 232, 1394, or any others. Figure 7-16. eAIB on Hornet 565 Base Hornet 565 Robot User's Guide, 14608-000 Rev C Page 121 of 156