EPSON — The error message "Energized substrate is detected (when using the Ionizer)." appears and remains

L-6534VW Operation Guide FAQ Image processing with reverse white printing of variable print data can take a long time A.1 Print dividing the job into a job for color plate and a job for reverse white plate. In the press, variable job printing is available at a speed of 15 m/min, but reverse white printing is performed at a speed of 7.6 m/min. A variable job including a reverse white plate has variable print speeds depending on the plate. Even in one job, rerun of image processing is required in reverse white plate printing, which takes a long time. In this case, assign an individual job to color plate and reverse white plate. Prepare a Preset for each job and print.

A.2 Change Print Speed to 7.6 m/min and then print the job. Printing the color plate at a speed of 7.6 m/min, equal to the speed of the reverse white plate, eliminates the need for the rerun of image processing required when switching to the reverse white plate. In Print Speed in Preset for Printing, select 7.6 m/min (Reverse White) . I want to improve the adherence between substrate and ink A.1 Reducing the print speed and using an additional UV lamp curing unit may improve the adherence between substrate and ink. Perform settings on the following items in Preset for Printing, and check the print results.

A.2 Depending on the substrate, there may be a problem with adherence between the substrate and ink at the trailing edge of the job. When using an additional UV lamp curing unit, there may be a part at the trailing edge of the job (up to approximately 5 cm) that is not subjected to UV irradiation. This is done to prevent the quality of the substrate from declining due to excess UV irradiation in the margins, and to prevent the quality of the next print job from declining. Set a large number of copies to ensure the required number of copies. The error message "Energized substrate is detected (when using the Ionizer)." appears and remains A.1 Clean the ionizer.

Also adjust the ion balance while printing. If the needles on the ionizer are still dirty or in an abnormal condition even after cleaning in periodic maintenance, the static discharge effect of the ionizer may decline. Perform the cleaning when you encounter an error, and then adjust the ion balance at the start of printing. 419 Item Set value Print Speed Slower than Current Speed Additional UV Lamp Curing Apply Additional UV Lamp Curing Unit Strength 100 %