HP — Numerical printer messages

Table 7-3 Numerical printer messages (continued) 232 Printer error troubleshooting C9660-90901 Message Description Action 59.XY PRINTER ERROR For help press alternates with 59.X Y PRINTER ERROR To continue turn off then on A printer motor error has occurred.

X Description 0 motor error 1 motor startup error 2 motor rotation error 3 fuser motor startup error 4 fuser motor rotation error 5 print cartridge motor startup error 6 print cartridge motor rotation error 9 ETB motor startup error A ETB motor rotation error B developing disengaging motor startup error C developing disengaging motor rotation error Y Description 0 no color K black C cyan M magenta Y yellow 1 Turn the printer off and then back on. 2 This message might also appear if the transfer unit is missing or incorrectly installed. Ensure that the transfer unit is correctly installed. ETB motor error 1 Clean the ETB unit intermediate connector, J4017.

If the connector is damaged, replace it. 2 Reconnect the connetors J4022 for the ETB motor, J4017 between the ETB and the printer, and J4014 on the DC controller PCB. 3 Replace the ETB motor. 4 Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294. Fuser motor error 1 Reconnect the connectors J4030 for the fuser motor and J1002 on the DC controller PCB. Replace any damaged parts. 2 Replace the fuser drive assembly. 3 Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294.

Print cartridge motor error 1 Reconnect the print cartridge connector on the DC controller PCB (J1013 for cyan, J1031 for magenta, J1032 for yellow, and J1033 for black). 2 Replace the drum drive assembly for the indicated print cartridge. 3 Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294. Developing disengaging motor error 1 Reconnect the connectors J4024 and J1019 between the developing disengaging motor and the DC controller PCB. 2 Replace the developing disengaging drive assembly. 3 Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294.

62 NO SYSTEM To continue turn off then on No system was found. 1 Turn the printer off and then back on. 2 Reseat the firmware DIMM, making sure it is in the 168-pin slot J1.