Blank spots Table 7-31 Causes for blank spots Poor fusing Table 7-32 Causes for poor fusing Distortion or blurring Table 7-33 Causes for distortion or blurring 258 Image defects C9660-90901 Cause Solution High-voltage PCB is defective. Replace the high-voltage PCB. DC controller PCB is defective. Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294. Cause Solution Media is not within specifications. For example, media that is too thick causes poor fusing. Use media that meets specifications. See “Supported media weights and sizes” on page 29. Fuser is not within nip width specifications. Replace the fuser.
Fuser sleeve is scarred or damaged. Replace the fuser. Pressure roller is scarred or damaged. Replace the fuser. Thermistor is deteriorated. Replace the fuser. DC controller PCB is defective. Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294. Cause Solution Color plane registration is out of specification. Calibrate the printer from the Print Quality menu. See “Calibrate Now” on page 294. ETB is defective. If the ETB belt does not rotate smoothly, replace the ETB. Calibrate the printer after replacing the ETB. See “Calibrate Now” on page 294. ETB motor drive gear is worn or damaged. Replace the ETB motor.
Drum motor drive gear is worn or damaged. Replace the drum motor for the affected color. Color registration detection unit is defective. Replace the color registration detection unit. Laser/scanner unit is defective. Replace the laser/scanner for the affected color. Calibrate the printer after replacing the laser/scanner. See “Calibrate Now” on page 294. DC controller PCB is defective. Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294.