HP — Image defects

Smearing Table 7-34 Causes for smearing Misplaced image Table 7-35 Causes for a misplaced image C9660-90901 Chapter 7 Troubleshooting 259 Cause Solution Poor contact in the printer ground and cartridge ground contacts. Clean each printer cartridge ground contact and the printer ground contact. If they are still dirty after cleaning, or if they are damaged, replace the cartridge, or replace the printer ground contact. Fuser inlet guide is dirty or has debris. Clean the fuser inlet guide. Cartridge shutters are not opening. Make sure the cartridge shutter bar is operating properly. Cause Solution Paper is skewed. See Table 7-15 on page 245 to resolve the reason for the skew.

Oblique rollers are worn. (Applies to duplex printing only.) Replace the oblique rollers. DC controller PCB is defective. Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294.