HP — Individual diagnostic tests

Sensor Test (special mode test) This diagnostic test allows you to test the printer's sensors and switches for proper operation. Each sensor is represented by a letter, as indicated in Table 7-47. A one below the letter indicates paper is present. For the paper size sensor, the range of values is from 0 to 7. Table 7-48 indicates the switch state and paper size associated with each of these values. Note To eliminate the display flicker during this test, you can leave the door switch in the open state.

Table 7-47 Sensor test letter codes Figure 7-14 Tray 2 paper size switch arrangement Table 7-48 Tray 2 paper size codes Note Depressing all three switches of the Tray 2 paper size levers to cause the control panel to display the custom paper menu. Press the button to return to the sensor diagnostic display.

288 Diagnostics C9660-90901 Letter Sensor Sensor/switch number Idle value (doors closed, paper in Trays 1 and 2) A top of page PS 3 0 B fuser inlet speed PS11 1 C fuser delivery PS12 0 D output bin full PS13 0 E MP tray paper presence PS2 0 F Tray 2 paper presence PS1 0 G Tray 2 paper size SW1, SW2, SW3 0 - 7 (see Table 7-48) H Door SW4 1 Size code Switch state Paper size SW1 SW2 SW3 0 on on on Custom (see note below) 1 off on on Letter 2 on off on A5 3 off off on Legal 4 on on off B5 (JIS) 5 off on off Executive 6 on off off A4 7 off off off tray not installed