Manual - BMV-712 Smart Set to 100% - The state of charge is set to 100%. This setting is only available when the battery monitor's firmware is version 4.12 or higher and the Bluetooth interface's firmware is version 2.42 or higher. In case the battery monitor or Bluetooth interface firmware is older, this setting is called "Start synchronized" and offers the option to either turn it OFF (clear) or ON (set to 100%). With this setting, you can manually set the state of charge value. This setting is only active after the battery monitor has, at least once, been synchronised. Either automatically or manually. 7.2.11.
State of charge This setting is only available when accessing the battery monitor via the VictronConnect app. 7.2.12. Synchronise SoC to 100% Setting 10 This option can be used to manually synchronise the battery monitor. When navigating to this setting on the head unit , press the SELECT button to synchronize the battery monitor to 100%. In the VictronConnect app press the ”Synchronise” button to synchronise the battery monitor to 100%. See the Manual synchronisation [24] paragraph for more information on this setting. 7.2.13.
Zero current calibration Setting 09 This option can be used to calibrate the zero reading if the battery monitor reads a non-zero current even when there is no load and the battery is not being charged. A zero current calibration is (almost) never needed. Only perform this procedure in case the battery monitor shows a current while you are absolutely sure that there is no actual current flowing. The only way to be sure is to physically disconnect all wires and cables connected to the LOAD AND CHARGER side of the shunt. Do this by unscrewing the shunt bolt and removing all cables and wires from that side of the shunt.
The alternative, switching loads or chargers off, is NOT accurate enough as this does not eliminate small standby currents. Ensure that there really is no current flowing into or out of the battery (disconnect the cable between the load and the shunt), then press SELECT in the head unit menu or press CALIBRATE in the VictronConnect app. Performing a zero current calibration. Page 31 All features and settings Setting Default Modes Battery SOC on reset (setting 70) Keep SOC Keep SOC Clear Set to 100% Setting Default Range Step size State of charge -- % 0.0 - 100% 0.1%