Downloaded from https://www.everyspec.com MIL-STD-100E NOTICE 2 101.16 .1.5 Preparation of duplicate original. Duplicate originals shall not be prepared for the purpose of maintaining duplicate records. Their application is limited to replacing missing original drawings. 101.16.1.6 Digital data. 101.16.1.6.1 Plotters. If originals are maintained as digital data, copies resulting electrostatic plotters need not meet the material, erasure and aging requirements or UU–P–561. from of L–P–519 101.16.1.6.2 Maintenance. Unless otherwise specified. requirements for erasure.
paper do not apply to associated lists prepared by automatic data processing, or drawings prepared and maintained as digital data. aging and 101.16.1.7 Associated lists, materials. Associated lists prepared from digital data need not meet the requirements of 101.16.1.1 or 101.16.1.2. 101.16.2 Digital product definition data. 101.16.2. Media. The physical media for delivery of digital product definition data shal conform to MIL–STD-1840. 101.16.2.2 Initial Graphics Exchange Specification (IGES). IGES ergineering data files shall be Class II application data subsets in conformance to MIL-D-28000 and MIL-STD-1840. 101.16.2.3 Raster data files.
Rastcr data files shall be in accordance with MIL-R-28002. 100-6 Supersedes pages 100-6 of 30 March 1992