Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D * Bandwidth requirements: Such that when used in conjunction with the notch or stopband filter in the signal source, the noise signal energy passed is low enough for a dynamic measurement range capability of 50 dB minimum. * Bandpass filter: The 3 dB bandwidth of the bandpass filter should be sufficiently wide (50 Hz ± 5 Hz) to minimize integration time required for a reasonably steady ( ± 0.5 dB typical) meter indication. The 60 dB bandwidth shall be sufficiently narrow (100 Hz ± 10 Hz) to allow, when used in conjunction with the notch filter, for the measurement dynamic range desired (50 dB minimum). NOTE:

A 100 kHz crystal filter design can meet these typical characteristics. * Frequency translator: The dynamic range of the frequency translator shall be wide (90 dB typical). NOTE: The phase noise associated with the conversion injection signal shall be sufficiently small so as to not affect the S/IMD measurement. FIGURE 2206-2. S/IMD measurement. NOTES: 1. Signal source monitor point (see figure 2206-1). 2. Measure anode R . Remove all voltages on TUT. Use Rx bridge, vector, voltmeter, or equivalent. 3. All circuit components, circuitry, layout, construction and metering in accordance with good engineering practice. 4.

Filament or heater voltage meter, and meters for measuring current and voltage in the anode and grid circuits shall be calibrated for one percent accuracy or better as installed in the equipment. 5. All power supplies except anode electronically regulated one percent or better for line/load variations. 6. VTVM used should be a true rms responding or average, or equivalent, with power output (useful) computed from P = E 2 /R. An equivalent method for measuring power may be used, such as calorimetric methods, provided it is capable of ± 5 percent accuracy, or better. FIGURE 2206-3. Basic circuit for signal to IM distortion (S/IMD) and power output test. METHOD 2206 2206-3 19 April 1968