Downloaded from https://www.everyspec.com MIL-STD-1311D DIRECT INTERELECTRODE CAPACITANCES METHOD 4266A (Microwave tubes) 1. Purpose. The purpose of this test is to measure the effective capacitances of electrodes relative to each other on and within the TUT. 2. Procedure. The capacitance shall be measured with cathode cold and no direct voltages applied. All elements, except the one under test, shall be connected to ground. If flying leads are part of the tube, lead and sleeve lengths shall be specified. 3. Precautions. 3.1 When measuring the capacitance of any lead with respect to ground, the effect of by-pass capacitors, if any, in any lead shall be taken into account.
Unless otherwise specified, they shall be included in the measurements. METHOD 4266A 4266-1 25 March 1970