Downloaded from https://www.everyspec.com MIL-STD-1311D Briefly, the operation of the circuit for the three types of jitter is as follows, 3.1 Time jitter. A sample of energy is detected, amplified, fed through a precision variable delay line into a special coincidence circuit where it is delayed. The oscillator voltage pulse to which the rf output pulse must be compared, triggers a pulse generator which produces an output pulse that has negligible relative time jitter and adjustable pulse width. The two pulses are added together in the coincidence circuit and the trailing edge of the generated pulse adjusted to align with the leading edge of the rf pulse as shown on figure 4318-7.
This produces a triangular waveform whose output is proportional to time variations in the leading edge of the rf pulse. This signal is then fed into a gate generator, the triggering level of which is approximately equal to a 50-percent level on the leading edge of the rf envelope. Each time a triangular-wave pulse exceeds this level, a pulse is generated in the gate generator and fed into a decimal counter. Also, a similar pulse is generated for each group of successive triangular pulses that exceed this triggering level. These pulses or "runs" count are also fed into a decimal counter.
The decimal counter has a time base established by the preset counter driven by the voltage pulse applied to the oscillator under test. The time base is set for a minimum of prf 000 ,1 seconds. The precision delay time is then varied in discrete steps such that the amplitude of the triangular pulse varies from a point where 0 percent of the pulses are counted until 100 percent are counted. This procedure is used to obtain the cumulative distribution data. 3.2 Frequency jitter. The microwave interferometer is used as the sensing element.
It has a detected output signal as shown on figure 4318-8a which is amplified and then fed into the coincidence circuit where it is added to a pulse from the pulse generator, see figure 4318-8b. The resultant signal will contain amplitude variations which are proportional to frequency changes in the output pulse of the oscillator under test. This signal containing amplitude variations is fed into the coincidence circuit much in the same manner as that for time jitter. In this case, cumulative distribution data is obtained by varying the frequency of the interferometer in discrete steps until 0 to 100 percent of the pulses are counted for a given preset time interval. 3.3 Amplitude jitter.
For amplitude jitter measurements, the sampled energy is fed through a precision adjustable attenuator to a detector biasing circuit where the top of the pulse is detected and bottom clipped as shown on figure 4318-9a. The top of the envelope is then fed through the video amplifier and into the coincidence circuit where it is combined with the output of the pulse generator shown on figure 4318-9b. This results in a pulse having amplitude variations which are representative of amplitude variations in the pulse generated by the oscillator under test, see figure 4318-9c. This signal is then fed into the gate generator and handled in the same manner as time and frequency jitter.
Cumulative distribution data is obtained by varying the precision attenuator in discrete steps in the same manner as previous jitter measurements. 4. Correlation of peak-peak jitter (jt for peak-peak time jitter) measurements with the pulse-pulse rms value. Where sufficient data has been taken to show that peak-peak measurements of jitter are correlatable, with the pulse-pulse rms value of jitter as measured by these statistical techniques, it may be used as the basis for acceptance.
Some of the factors to be considered are the effects of different test modulators, tubes, interpretations of test operators, as well as any other factors which could affect the relationship of peak-peak jitter with the pulse-pulse rms jitter. 5. Measurement of jitter which includes some periodic-ripple contribution. In addition to the cumulative incremental distribution data, simultaneous data shall be taken to determine the number of "runs" that occur during each fixed time interval. A "run" is defined as any group of successive pulses that exceeds a particular level of jitter during a fixed time interval.
If amplitude jitter is being measured and a group of 15 pulses vary in amplitude in the following manner, the total of individual pulse "counts" and "runs" would be as shown on figure 4318-10. METHOD 4318 4318-3 19 April 1968