Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 4461A LOADED Q (Gas-switching tubes) 1. Purpose. To determine an important characteristic of high-Q tunable TR tubes which directly affects the sharpness of tuning, and is an indication of the operational bandwidth. For ATR tubes, the loaded Q serves to specify the band of frequencies over which the ATR can be utilized. 2. Equipment. The equipment for making this measurement shall consist of a signal generator or sweep oscillator, a frequency meter, an attenuator, a matched detector, and a meter or calibrated oscilloscope. The equipment layout is shown on figure 4461-1. FIGURE 4461-1. Equipment for loaded Q measurements. 3.

Procedure. 3.1 TR tubes. The tube shall be placed in a transmission circuit between a matched signal generator and a matched detector, with sufficient attenuation between the generator and tube to prevent frequency or power changes in the signal source due to tuning of the tube. With the signal source at the reference frequency, the tube shall be tuned to resonance (Fo), as indicated by a pronounced peak of the output indicator, and the output power shall be measured. The frequency of the signal generator shall then be increased until the power at the termination falls to one-half of the value at resonance. The frequency at this point shall be recorded as F1.

The procedure shall then be repeated in the direction of decreasing frequency, the resulting half-power point being noted as F2. The loaded Q shall be within the limits specified when determined as follows: 2 1 F F Fo QL = As the signal generator is tuned from F1 to F2, its output power shall be stable in amplitude to better than 1 percent to insure accurate determination of the half-power frequencies. If this condition can not be satisfied, the frequency versus power-output characteristic of the signal generator shall be determined and taken into account in locating F1 and F2. 3.2 ATR tubes.

The tube shall be inserted as a series tee in the specified mount between a matched generator and termination. The loaded Q is then defined in terms of the rate of change of susceptance with frequency, and may be expressed as: ) 1( 2 g df dB Fo QL + = METHOD 4461A 4461-1 25 March 1970