Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D TEMPERATURE COEFFICIENT OF FREQUENCY METHOD 4466 (Gas-switching tubes) 1. Purpose. To determine the shift in resonant frequency of a tube over a specified range of temperature. 2. Equipment. A test chamber capable of maintaining temperature at the specified values. A signal source and means of measuring frequency and indicating power are required. 3. Procedure. 3.1 Method A (for tunable tubes). The tube shall be placed in a temperature-controlled chamber at room temperature and connected in a transmission circuit between a matched signal generator and detector.

With the signal source set at the reference frequency, the tube shall be tuned to resonance as indicated by a pronounced peak of the output indicator. The temperature in the chamber shall then be reduced to 0 ° C and the tube body allowed to come to thermal equilibrium. The resonant frequency of the tube at 0 ° C shall be determined by retuning the signal source for a peak of the output; the procedure shall then be repeated at +100 ° C. The frequency change of the tube over the temperature range shall be within the limit(s) specified. 3.2 Method B (fixed tuned tubes). The tube shall be mounted in the specified external cavity and placed in a circuit as specified in method A above.

The signal source shall be tuned to the resonant frequency of the tube and cavity as indicated by a pronounced peak of the output indicator. The frequency shall be recorded and the procedure of method A shall then be followed. The frequency change over the temperature range shall be within the limit(s) specified. METHOD 4466 4466-1 19 April 1968