Downloaded from https://www.everyspec.com MIL-STD-1311D RECOVERY TIME METHOD 4471B (Gas-switching tubes) 1. Purpose. The purpose of this test is to measure the time after the removal of rf power from a TR tube, or a Pre-TR tube, at which the low-level attenuation of the tube is 3 dB above its attenuation in the unexcited state. Also to measure the shift in position of the VSW minimum of an ATR tube at a specified time after the removal of rf. 2. Procedure. To establish the basic circuits and procedures. 2.1 Method A (TR tubes, pulsed signal). 2.1.1 Equipment.
The circuit for measuring the recovery time of a TR tube using a pulsed signal to simulate the return signal is given on figure 4471-1. FIGURE 4471-1. Equipment layout for recovery time measurements (TR and Pre-TR) method A. 2.1.2 Procedure. The tube shall be mounted as a series tee with the rf power in the main line set for the specified conditions. A low-level pulse modulated signal (simulated received echo) at the reference frequency, which is synchronized with the high-powered transmitter rf pulse through a trigger variable delay unit, shall be introduced into the main line through a coupling device. The power transmitted through the TR tube shall be viewed on the oscilloscope.
As the low-level signal is varied in time with respect to the transmitter pulse, its amplitude will vary due to the attenuation characteristic of the TR tube, which is deionizing. Attenuated amplitude measurements of the received signal are made with respect to the amplitude of received signal received when the TR tube has completely recovered. The recovery time, measured from the trailing edge of the transmitted pulse to the leading edge of the received signal at the specified attenuation level, shall be within the limits specified.
This measurement can conveniently be made using the leading edge of the transmitted pulse as a reference and subtracting the pulse duration from the time readings. METHOD 4471B 4471-1 25 March 1970