Downloaded from https://www.everyspec.com MIL-STD-1311D 2.2 Method B (TR tubes, CW signal). 2.2.1 Equipment. 2.2.1.1 Tube series-mounted as in method A. The circuit for measuring the recovery time of a series mounted TR tube using a CW signal is shown on figure 4471-2. 2.2.1.2 Tube terminating the line. The circuit for measuring the recovery time of a TR tube shunting the line using a CW signal is shown on figure 4471-3. FIGURE 4471-2. Equipment layout for recovery time measurements (TR and Pre-TR) method B (see 2.2.1.1). FIGURE 4471-3. Equipment layout for recovery time measurements (TR and Pre-TR) method B (see 2.2.1.2). 2.2.2 Procedure.

The tube shall be mounted as shown either on figure 4471-2 or 4471-3. A low-level CW signal adjusted to the specified frequency is coupled into the main line through an appropriate coupling device. Pulsed rf power at the specified peak power level is now turned on in the main line. The resulting pattern is ideally represented as shown on figure 4471-4. The pulse shown represents the transmitted pulse through the TR tube, being essentially the leakage power pulse. METHOD 4471B 4471-2 25 March 1970