Downloaded from https://www.everyspec.com MIL-STD-1311D (a) (b) t0 = time at start of pulse t1 = time at end of pulse t2 = time when loss through TR tube = specified recovery ratio (3dB) t2 - t1 = recovery time FIGURE 4471-4. Oscilloscope pattern using CW method of measuring recovery time. The leakage power pulse is shown on figure 4471-4 under three different conditions. Curve (a) is the pattern used in measuring the recovery time after the -3 dB level has been established by attenuating the signal to obtain the resultant pattern shown by the dotted line. Curve (b) is drawn only to show that the conventional leakage power will be seen if the CW signal is removed.
A time reference, t1, is established at the trailing edge of the leakage pulse. Time t2 is found by observing the point at which the curve (a) crosses the -3 dB reference line. The difference between t1 and t2 is the recovery time of the tube. 2.2.3 Precautions. To obtain a suitable pattern for making measurements, it may be necessary to use enough amplification so that the spike and the flat portions of the leakage pulse are greatly amplified. This results in two separate lines on the oscilloscope screen which are used in the measurement of points t1 and t2 as referenced in 2.2.2.
The power from the CW source should be kept as low as possible so as not to saturate the crystal used for viewing. 2.3 Method C (pre-TR tubes). 2.3.1 Equipment. The test circuits shown on figures 4471-2 or 4471-3 may be used in measuring the recovery time of a pre-TR tube. 2.3.2 Procedure. The procedure for measuring recovery time of a pre-TR is the same as for a TR tube, as outlined in methods A or B. If a TR tube is used following the pre-TR tube, the received signal must see a match, looking into the TR cavity, for example, tuned to resonance and properly loaded. If loading cannot be adjusted, resistive padding can be used between the pre-TR and the TR tube.
Precautions shall also be taken to insure that the recovery characteristic of the TR tube will not affect the measurement of the recovery time of the pre-TR tube. 2.4 Method D (dual TR tubes or dual pre-TR tubes). 2.4.1 Equipment. The circuit shown on 44471-5 is used for measuring the recovery time of dual TR or pre-TR tubes. METHOD 4471B 4471-3 25 March 1970