Downloaded from https://www.everyspec.com MIL-STD-1311D X-RADIATION MEASUREMENT METHOD 5001 (Display cathode-ray tubes) 1. Purpose. To obtain the X-radiation intensity of display cathode-ray tubes in order to determine the levels emitted by the tubes when operated at high voltages. 2. Procedure.
Tubes shall be tested in accordance with EIA-501-A, "Recommended Practice for the Measurement of X- Radiation from Raster-Scanned Direct-View Data Display Cathode-Ray Tubes," EIA-502-A, “Recommended Practice for Measurement of X-Radiation from Non-Raster-Scanned Direct-View Cathode-Ray Tubes,” and/or EIA-503-A “Recommended Practice for the Measurement of X-Radiation from Direct-View Television Picture Tubes.” The tube shall be operated as specified in the TSS. 3. Acceptance criteria. At the point of maximum radiation, record the maximum stable radiation observed in mR/hr. The maximum allowable radiation limit in mR/hr shall be specified on the TSS. 4. Precautions.
4.1 X-radiation of the soft x-ray category may constitute a health hazard on prolonged exposure at close range. Therefore, equipment design shall provide for adequate shielding. Adequate precautions shall be taken to protect personnel from this hazard and film badges or other monitoring devices shall be assigned to all personnel involved in performing X-Radiation measurements. 4.2 A warning label informing of these precautions shall be placed in an appropriate position on the equipment. METHOD 5001 5001-1 28 March 1975