Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D METHOD 5101A ALIGNMENT (Cathode-ray tubes) 1. Base alignment (electronic types). The angle between the trace produced by the designated deflecting plates and the plane passing through both the center of the designated base pin and the axis of the tube shall not exceed 10 degrees. 2. Side terminal alignment (electrostatic types). The angle between a designated trace and a plane through the center of the side terminal and the axis of the tube shall not exceed 10 degrees. 3. Side terminal and base alignment.

The angle between the plane passing through both the center of the designated base pin and the axis of the tube, and the plane passing through the center of the side terminal and the axis of the tube shall not exceed 10 degrees. The designated base pin shall be on the same side of the tube as the side terminal. 4. Neck and bulb alignment (electrostatic types). This test should normally be performed during qualification inspection only. The alignment of the neck with the body of the tube shall be measured by rotating the tube about an axis through the center of the pin circle (in the plane of the bottom of the base) and the center of the face of the bulb.

The diameter of the circular area swept through by transverse section of the neck at a point .250 inch (6.35 mm) nearer the base than the CD line (the horizontal line at the junction of the bulb body and neck) shall not exceed the value specified. 5. Neck and base alignment (electrostatic types). The angle between the longitudinal axis of the base and the longitudinal axis of the neck shall not exceed 2 degrees. 6. Neck and bulb alignment (magnetic types). This test should normally be performed during qualification inspection only.

The tube shall be rotated about the axis of the neck, and measurement shall be made of the variation in distance from the axis of rotation to the periphery of the bulb in a plane normal to the axis of rotation and nearer the base than the point where the axis of rotation intersects the face of the tube by the following distances: .3125 inch (7.938 mm) for 3- and 5-inch tubes, .75 inch (19.1 mm) for 7- inch tubes, 1.25 inches (31.8 mm) for 9-inch tubes, 1.5 inches (38.1 mm) for 10-inch tubes, and 1.75 inches (44.5 mm) for 12-inch tubes.

The axis of the neck is defined as the axis of rotation when the neck is supported on two sets of "V" wheels, 3-wheel checks or equivalent, placed .75 inches (19.1 mm) and 4.25 inches (107.9 mm) below the reference plane. The variation shall be not more than .125 inches (31.8 mm) for 3- and 5-inches, .225 inches (5.72 mm) for 7-inch tubes, and .400 inch (10.16 mm) for 9-, 10-, and 12-inch tubes. 7. Angle between traces. When measured with a device having an accuracy of at least ± 0.2 degree, the angle between horizontal and vertical traces shall be 90 ± 3 degrees. The angle shall be measured counterclockwise from the horizontal traces.

The angle between corresponding traces of multigun tubes shall be not greater than 1 degree. This test shall be performed using traces at the center of the useful scan area. The length of traces shall be 75 percent of the useful scan dimensions. The beam current shall be adjusted to a level just below that which would cause screen damage. 8. Face tilt. This test should normally be performed during qualification inspection only. When the tube is rotated about the axis of the neck (see 6.

above), the total variation in the distance from the faceplate to a plane perpendicular to the axis of rotation shall be not greater than .080 inch (2.03 mm) for 3- and 5-inch tubes, .150 inch (3.81 mm) for 7-inch tubes, and .225 inch (5.72 mm) for 9-, 10-, and 12-inch tubes. This variation shall be measured on the face at a distance from the axis of rotation equal to the minimum useful screen radius for the tube. 9. Neck straightness. The neck and base straightness shall be determined by the insertion of the tube neck in a cylinder 5.00 inches (127 mm) long and 1.4375 inches (36.513 mm) maximum inside diameter.

This cylinder shall move freely between the reference line and the base of the assembled tube. 10. Trace and bulb alignment (rectangular electrostatic types). When measured with a device having an accuracy of at least ± 0.2 degree, the angle between the specified trace and the specified bulb wall shall not exceed 2 degrees. The trace shall be located at a scan area center and have a length equal to 75 percent of the useful scan dimensions. 11. Spot deflection. With a positive potential applied on the deflection plate specified on the TSS, the spot shall be deflected in the direction of the designated pin. METHOD 5101A 5101-1 25 March 1970