Department of Defense MIL-STD-1311D — MIL-STD-1311D Test Methods for Electron Tubes — DoD Standard Manual PDF

Downloaded from https://www.everyspec.com MIL-STD-1311D BLEMISHES, VISUAL-OUTPUT METHOD 5409A (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to determine the blemish quality of a tube by measuring, or counting, the following parameters: a. The blemish output signal levels relative to the output signal levels of adjacent areas. b. The size of the blemishes. c. The spacing of the blemishes. d. The number of blemishes within a stated zone of the storage surface. 2. Definitions. a. A blemish is a localized imperfection of the storage assembly, phosphor screen, or faceplate that produces an abrupt variation in output luminance. b.

Static blemishes are blemishes whose presence is not a function of writing or erasing rates. c. Dynamic blemishes are blemishes whose presence is a function of writing or erasing rates. d. Light blemishes are blemishes which, under specified test conditions, are brighter than the background luminance. e. Dark blemishes are blemishes which, under specified test conditions, are darker than the background luminance. 3. Equipment. a. A photometer shall be used to measure the background the background luminance of the TUT over a circular area 10 ± 5 mm (approximately .4 ± .2 inch) in diameter. b. If specified in the TSS, a photometer with a small aperture size shall be specified in the TSS. c.

The erase system shall produce the erase pulse width, amplitude, and repetition rated specified in the TSS. d. The write deflection system shall produce a linear raster of merged scanning lines at a repetition rate specified in the TSS. e. Optical magnification may be used in the measurement of blemish dimensions. 4. Procedure. 4.1 Tube not energized. Those sections of MIL-PRF-1 which apply to inspection of cathode-ray tubes for screen and faceplate defects shall also apply to visual output cathode-ray charge storage tubes with the exception of those items which require the tube to be energized. 4.2 Tube energized. 4.2.1 General. a.

Operating conditions including the duty cycle of the erase pulse train, the erase pulse amplitude, and the ambient light level shall be as specified in the TSS. b. Unless otherwise specified in the TSS, the existence of blemishes shall be determined visually without requiring a small aperture photometer. METHOD 5409A 5409-1 12 December 1972