Downloaded from https://www.everyspec.com MIL-STD-1311D 4.2.2 Static blemishes. Static blemishes shall be measured under conditions of dynamic erasure with no writing. When the erase pulse train is turned on, static blemishes which are present will appear as blemishes which do not change in size or intensity with time. 4.2.3 Dynamic blemishes. Dynamic blemishes shall be measured under conditions of dynamic erasure with writing. a. The write raster shall just overscan the useful viewing area in both directions. b. The write-gun drive shall be adjusted to write the display to the luminance specified and over the area specified. c.
At a specified time after writing, the blemishes shall be observed. 5. TSS requirements. a. In addition to the operating conditions for the TUT, the TSS shall specify the following: (1) The maximum number of blemishes allowed in each blemish category. (2) The minimum blemish spacing. (3) The erase pulse limit(s). (4) Writing luminance level. (5) The time interval between writing and the dynamic blemish inspection. b. If the TSS specifies that the light output from blemishes is to be measured with a photometer, the TSS shall specify the effective aperture of the photometer. METHOD 5409A 5409-2 12 December 1972