Downloaded from https://www.everyspec.com MIL-STD-1311D ERASING TIME, VISUAL OUTPUT METHOD 5416 (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to measure the minimum time required to erase stored information from a specified level of luminance to cutoff. 2. Definitions. a. Saturation level is that level of luminance beyond which no further increase in luminance is produced by additional writing. The tube can be written to saturation level by writing up the entire viewing area with the erase pulse amplitude set at zero and then cutting off the write beam. b. Pulse train gate time is the total time period during which the erase train is applied to the TUT. 3.

Equipment. a. A photometer shall be used to measure the luminance of the TUT over a circular area 10 ± 5 mm (approximately .4 ± .2 inch) in diameter. b. A deflection system shall produce a merged raster on the TUT with linear sawtooth deflections in orthogonal directions. 4. Procedure. Erasing time may be determined by either of the following test methods. 4.1 Method A. Erasure with a single pulse. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write all of the area specified in the TSS to saturation level or the luminance level specified in the TSS. c. Stop writing.

Using an erase pulse of 1 second or less duration, establish the pulse amplitude necessary to reach the storage target cutoff point. This is accomplished by alternately writing to saturation (or the level specified) and erasing, while adjusting the amplitude of the erase pulse. d. Alternately write to saturation (or the level specified) and erase to the cutoff point while adjusting the erase pulse width and amplitude for the shortest erase time. This will require increasing the pulse amplitude and decreasing the pulse width until a width is reached which, if further decreased, will not provide erasure regardless of pulse amplitude. This pulse width is the single pulse erasing time.

4.2 Method B. Erasure with a pulse train. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write all of the area specified in the TSS to saturation level or the luminance level specified in the TSS. c. Stop writing. Using an erase pulse train whose product of pulse repetition frequency, width, and gate time is equal to or less than 1 second, establish the pulse train amplitude necessary to reach the storage target cutoff point. This is accomplished by alternately writing to saturation (or the level specified) and erasing, while adjusting the amplitude of the erase pulse train. METHOD 5416 5416-1 12 December 1972