Downloaded from https://www.everyspec.com MIL-STD-1311D d. Alternately write to saturation (or the level specified) and erase to the cutoff point while adjusting the pulse train duty cycle and amplitude for the shortest erase time. This will require increasing the pulse train amplitude and decreasing the pulse train duty cycle until a duty cycle is reached which, if further decreased, will not provide erasure regardless of pulse train amplitude. The minimum erase time is the product of erase prf, pulse width, and gate time. That is: Erase time, minimum = (prf) (tp) (tg) Where: prf = erase pulse repetition frequency tp = erase pulse width tg = total time the erase train is applied. 5.
Precautions. a. To assure that stray light sources do not significantly affect luminance measurements, the light level recorded by the photometer in the measurement position shall be such that, with the TUT off, the photometer reading does not exceed 3 percent of the TUT luminance value to be measured. b. This test is not applicable to tubes operating in a bistable mode. c. The erase time of some tubes may by design be in excess of 1 second. In such cases, employ in method A, a single pulse of duration sufficiently long to permit erasure. In method B, employ a pulse train whose product of prf, tp, and tg, is sufficiently long to permit erasure. d.
When pulse train erasure is used, the pulse train gate time shall be no greater than 10 percent of the TUT reading time (see reading time, method 5423) in order to reduce measurement error caused by ion discharge or dielectric leakage effects. e. The amplitude of the pulse(s) used to establish the minimum erasing time will be sufficient to result in target areas written to less than the level specified being erased below cutoff. This will reduce writing sensitivity in such areas. 6. TSS requirements. a. In addition to the operating conditions for the TUT, the TSS shall specify the following: The area of the display within which erasing time is to be measured. b.
If values other than those specified in this test method are required, the TSS shall specify: The luminance level to which the display is initially written (see 4.1c, 4.1d, 4.2c, and 4.2d). METHOD 5416 5416-2 12 December 1972