Downloaded from https://www.everyspec.com MIL-STD-1311D e. Without further adjustments, measure the luminance (B D ) at the center of the screen or at the faceplate location(s) specified in the TSS., immediately after the writing beam has stored in those location(s). (Luminance (B D ) will always be less than the saturated luminance of the TUT because the stored signal density is always less than 100 percent. The attainable density is determined by such characteristics of the TUT as its resolution, writing speed, and bandwidth.) In addition, at these specified location(s) measure the time for the stored information to decay into the background luminance level. This is time (T D ). f.

The dynamic writing and erasing response (D W-E ) shall be stated in terms of measured luminance at given grid drive, given decay time, and given scanning speed. The TSS shall specify the required value of (B D ) in addition to the setup condition (V), (S), and (T D ). That is: D W-E response = B D , a function of (V, S, T D ). Where: B D = peak luminance level of written noise (fL). V = grid drive of noise (rms volts). S = scanning speed (inches/second). T D = time of luminance to decay into background luminance (seconds). 4. Precautions.

To assure that stray light sources do not significantly affect luminance measurements, the light level recorded by the photometer in the measurement position shall be such that, with the TUT off, the photometer reading does not exceed 3 percent of the TUT luminance value to be measured. 5. TSS requirements. a. In addition to the operating conditions for the TUT, the TSS shall specify the following: (1) Area of tube to be written (see 3b). (2) Erase pulse width and frequency ranges (see 3c). (3) Noise signal (V), unblanking pulse, and erase amplitude (see 3d). (4) Peak luminance level (see 3d(2)). (5) Scanning speed and luminance decay time (see 3f). b.

If values other than those specified in this test method are required, the TSS shall specify: (1) Location(s) on the screen at which response is to be determined (see 3c). (2) Noise bandwidth (see 2d). (3) Photometer area (see 2a). (4) Deflection system (see 2b). (5) Erase observation period (see 3c). (6) Stability observation period (see 3 (note)). METHOD 5417 5417-2 12 December 1972