Downloaded from https://www.everyspec.com MIL-STD-1311D MODULATION TRANSFER FUNCTION, FROM LINE SPREAD FUNCTION, ELECTRICAL OUTPUT METHOD 5422 (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to provide a quantitative measure of the ability of the TUT to transfer sine wave signal information from its input to its output as a function of spatial frequency referred to its SSRD (storage surface reference dimension). This method gives the impulse response of the TUT which is its modulation transfer function (MTF). 2. Equipment. a.

The writing-deflection system shall produce a pattern of one or more widely spaced parallel lines written at the sweep speed(s) specified in the TSS. b. The reading-deflection system shall produce a rectilinear (e.g., TV) type raster with lines disposed essentially orthogonal to the written lines, and repeated at a rate as specified in the TSS. c. External focus and deflection components when used shall be located with respect to the TUT as specified in the TSS. d.

The output-signal amplifier shall be linear, compensated for the output impedance of the TUT, and have a frequency response that is flat within 1 dB between frequencies (f 1 ) and (f 2 ), to insure accurate reproduction of the line spread function from the TUT. f 1 = the read scan-line repetition rate (Hz). f 2 = D J R (MHz). Where: R is the anticipated limiting resolution of the TUT in cycles/SSRD. J is the read scan-line length as a fraction of the SSRD. D is the active read scan-line duration in microseconds. SSRD is the storage surface reference dimension as defined in method 5405.

(It is acceptable to compensate for bandwidth limitations of the amplifier by reducing the reading raster width J.) e. An oscilloscope capable of displaying the output pulse shall be provided. Care should be taken in the use of interconnecting cables, triggered sweeps, and delayed expansion of the output pulse. No overshoot or ringing should be observable. The oscilloscope should be provided with line selection and waveform expansion capability either internally or by means of associated equipment. f. A camera or other recording means shall be provided to record the output pulse. g.

It is suggested (though not necessary for this test) that a picture (e.g., TV) monitor synchronized to the read scan be used to monitor the video signals. h. Figure 5422-1 shows a representative test equipment configuration. It contains typical equipment as may be employed in a TV to TV format conversion and indicates one means for selecting a single scan line. Also shown is the optional use of a TV monitor. i. Automated computing equipment will simplify data reduction. METHOD 5422 5422-1 12 December 1972