MultiPlus-II inverter/charger Australia 4.2.1. Set the grid code To set the grid code, do the following: 1. Download and install the VE.Configuration tools for VE.Bus products software package on a Windows PC. 2. Connect the unit to the PC's USB port using the Interface MK3-USB and an RJ45 UTP cable . 3. Open the VEConfigure3 software program (this is part of the configuration tool package). 4. Connect to the unit. 5. In the menu, go to port selection and click on the appropriate com port. 6. When connected, go to the "grid" tab. 7. Select the appropriate AS/NZS 4777.2020 grid code. Note that there are grid codes with or without N-bypass.
Use N-bypass if the installation contains a continuous neutral whereby the AC input neutral is connected to the AC output neutral. Also, please refer to the "Special notes regarding AS 4777.2" in Section 3.4 [9] . 8. Click the "Send settings" button to upload the grid code into the unit. 4.2.2. ESS configuration If the unit is going to be used in an energy storage system (ESS), then follow the instructions in the ESS design and installation manual . 4.2.3. VictronConnect The VictronConnect app can be used to change most inverter/charger settings. See the VictronConnect manual for more information on how to install it, how to pair it with your device, and how to update the firmware.
This app can also set up parallel or 3-phase systems containing up to 3 units. Note that this app cannot be used to change the grid code. 4.2.4. VEConfigure VE.Configure is a software program that can be used to change all inverter/charger settings. See the VEConfigure manual for more information. It is part of the "VE Configuration tools for VE.Bus Products" software package and can be downloaded free of charge at https:// www.victronenergy.com/support-and-downloads/software#ve-configuration-tools-for-ve-bus-products The inverter’s grid code settings can be viewed using the VEConfigure software when connected to a Windows PC. 4.2.5.
VE.Bus Quick Configure Setup VE.Bus Quick Configure Setup is a software program with which systems with a maximum of three Multis (parallel or three- phase operation) can be configured in a simple manner. It is part of the "VE Configuration tools for VE.Bus Products" software package and can be downloaded free of charge at https:// www.victronenergy.com/support-and-downloads/software#ve-configuration-tools-for-ve-bus-products 4.2.6. VE.Bus System Configurator For configuring advanced applications and/or systems with four or more Multis, VE.Bus System Configurator software must be used.
It is part of the "VE Configuration tools for VE.Bus Products" software package and can be downloaded free of charge at https:// www.victronenergy.com/support-and-downloads/software#ve-configuration-tools-for-ve-bus-products 4.3. Explanation of settings Settings that are not self-explanatory are described briefly below. For further information, please refer to the help files in the software configuration programs. Inverter frequency Output frequency if no AC is present at the input. The output voltage of the MultiPlus-II in battery operation. Inverter voltage Page 13 Configuration