2 Installing the NB Unit and Connecting Peripheral Devices Communication setting The communication settings need to be set as following values before carrying out communications in the Use Host link. Settings at the NB Unit should be specified from the [Configuration and Setup Window] in NB-Designer. For details, refer to 3-10-8 COM1/COM2 Setting in the NB-Designer Operation Manual . For communication settings at the host side, refer to the related PLC manuals as needed. 2-4-2 Connecting more than one PLC Select the RS-232C method for COM1, and one from RS-232C and RS-422A for COM2 (NB3Q- TW B is not equipped with serial port COM2.).
PT with the model number of NB -TW01B, which supports Ethernet, can connect single PLC or multiple PLCs simultaneously through the Ethernet (through the router). When connecting with multiple PLCs, it can connect the Host manufactured by the same manufacture or different manufactures simultaneously. Note Multiple Communications systems cannot be used simultaneously by the same COM port. The example of NB5Q/NB7W/NB10W-TW01B connecting with 3 PLCs simultaneously is as shown below: NB Unit PLC1 COM1 RS-232C cable COM2 RS-232C/422A/485 cable PLC2 PLC3 Ethernet cable • Always keep the connector screws firmly tightened after the communication cable is connected.
• The maximum tensile load for cables is 30N. Do not apply loads greater than this. • The communication cables of the COM1 and COM2 connectors are not interchangeable. Confirm the pins of the ports before carrying out communications.(NB3Q-TW00B and NB3Q-TW01B only have COM1.) 2-12 NB-series Programmable Terminals Setup Manual(V107) Items Settings Data bit 7bit Stop bit 2bit Parity check Even Communication speed Any value, but the values for the NB Unit and the host must be the same. Station No. 00 Precautions for Safe Use