2 Installing the NB Unit and Connecting Peripheral Devices Take the communication between single PT and the PLC of Omron CJ2M-CPU33 (hereinafter abbreviated as “PLC0”) as example: 2-5 UDP Communication Connection 2-5-2 Parameter Settings for UDP at NB Side Configure the devices and set the communication parameters in the Configuration and Setup Window, then click [Add] in [PT Property] - [PT] - [Communication Setting] to set parameters for PT network- interface communication. PT settings (example) Please note that the IP address set here should be same as the actual IP address of PLC during the configuration. The result is shown as below:
PT settings for connection with 2 and more types of hosts (example) When you connect 2 or more types of PLCs with the NB, register them according to their protocols respectively even though you use one PT. The result is shown below. NB-series Programmable Terminals Setup Manual(V107) 2-31 2 Device Type Device No. IP Address Port Number Communication Protocol Mater/Slave Station No. / Node Number PT HMI0 192.168.250.1 9600 OMRON CJ/CS/NJ Series Ethernet UDP M(Master) 1 PLC PLC0 192.168.250.2 9600 OMRON CJ/CS/NJ Series Ethernet (UDP Slave) S(Slave) 2 Device Type Device No. IP Address Port Number Communication Protocol Mater/Slave Station No.
/ Node Number HMI0 192.168.250.1 9600 OMRON CP Series Ethernet UDP M(Master) HMI0 192.168.250.1 9600 OMRON NX1 Series Ethernet UDP M(Master) PLC0 192.168.250.2 9600 OMRON CP Series Ethernet(UDP Slave) S(Slave) PLC1 192.168.250.3 9600 OMRON NX1 Series Ethernet(UDP Slave) S(Slave)