Nucleo GX Manual Page 88 Configuration Item Default Description DVCC Disabled Enabling DVCC turns the GX device from a passive monitor into an active controller. By default, it is disabled unless a compatible BMS- Can managed battery is connected, in which case it is set and locked according to the manufacturer’s specifications. Limit charge current Disabled Sets a user-defined maximum charge current for the entire system, specified in Amps. This allows coordinated charge control across all supported devices. Limit managed battery charge voltage Disabled This option is intended only for initial balancing of 15s Pylontech batteries.
Do not use it for other purposes, as it may lead to undesirable side effects. SVS - Shared voltage sense Disabled When enabled, the GX device automatically selects the best available voltage measurement and shares it with other connected devices. STS - Shared temperature sense Disabled When enabled, the GX device transmits the measured battery temperature to the inverter/charger system and all connected solar chargers. Temperature sensor Automatic Select which temperature sensor is used for Shared Temperature Sense. In automatic mode, the GX device chooses the most suitable available sensor.
SCS - Shared current sense No When enabled, the GX device forwards the battery current measured by a connected battery monitor to all supported solar chargers for coordinated charging behaviour. SCS status Displays if SCS is enabled, or why it is disabled. Controlling BMS Automatic Selects which Battery Management System (BMS) is used to control the battery, or disable BMS control. In automatic mode, the GX device chooses the appropriate BMS based on the system configuration. Auto selected Displays the BMS currently selected by the system when ‘Controlling BMS’ is set to ‘Automatic’.
Settings → System Setup → Display DC Loads Display DC Loads Disabled Enable this for boats, vehicles and installations with DC loads and chargers - in addition to Multi and MPPT chargers. This won't be applicable to most off-grid installations; and any discrepancy between the DC current measured by the Multi, and by the BMV, will be attributed to a 'DC system'. This may be power-in from an alternator, or power-out from a pump, for example. A positive value indicates consumption. A negative value indicates charging, for example by an alternator. Note that the value shown will always be an approximation, and is affected by the variation in sample rate between elements of the system.
To replace the approximated values with accurate measurements, a SmartShunt can be used, which needs to be configured to Monitor mode “DC Energy Meter” and DC meter type “DC System”. Wireless AC sensors (if applicable) Select the position for each AC sensor (PV Inverter on AC-input 1, 2 or on AC-output). More information about the Wireless AC sensors. Settings → Devices → GPS - Read full feature description [32] GPS information - Displays GPS data including: Status, Latitude, Longitude, Speed, Course, Altitude, and Number of satellites in view. Device - Displays device related information for diagnostic.
Settings → Devices → Genset - Read full feature description Autostart functionality Disabled Enable or disable the generator’s Autostart feature. Further configuration is available under Genset → Settings → Conditions. Manual control - Allows manual generator operation for a specified duration.