Orion-Tr Smart DC-DC Charger Non-Isolated 7.1.3. Reverse battery polarity Reverse polarity is when the positive and the negative battery cables have been accidentally swapped. The battery negative has been connected to the positive terminal and the battery positive has been connected to the negative terminal. Example of correct and incorrect (reverse) battery polarity Be aware that a red or positive labelled cable might not necessarily mean that the cable is indeed a positive cable. A wiring or labelling mistake could have been made during installation. Reverse battery polarity can be accompanied with a blown battery fuse (one that is located in the battery cable).
The is not protected against reverse battery polarity; any damage caused by this is not covered under warranty. 7.2. Battery is not charged This section lists the possible reasons why the does not charge the battery, and the steps you can take to remedy the situation. For example: Issues with the battery or system wiring Incorrect settings The is remotely controlled by a BMS or other device via its remote on/off terminal First, check the status field at the top of the status screen in the VictronConnect app. If charging is disabled, the reason is shown there.
This can be because the remote input is inactive, the charger is disabled in the battery settings, or charging is disabled because input voltage lock-out or engine shutdown was detected. The table below lists the possible messages and the action to take. VictronConnect message Action to take Remote input inactive Check that the terminal block for the remote on/off function is plugged in. Check for continuity if a wire loop or simple switch is used between the L and H pins. If a BMS controls the remote input, check that the ATC connection works. If this does not resolve the issue, see Remote terminal is missing, disconnected or external control is active [18] .
Disabled in settings Enable the charger in the battery settings. See The charger is disabled [18] . Input voltage lock-out The input voltage is below the lock-out level. See Input voltage lock-out is active [18] . Engine shutdown detected The charger has detected that the engine is not running. See Engine shutdown is detected [19] . Page 17 Troubleshooting & Support