Orion-Tr Tr Smart DC-DC Charger Non-Isolated — 7.2.3. Input voltage lock-out is active

Orion-Tr Smart DC-DC Charger Non-Isolated 7.2.1. Remote terminal is missing, disconnected or external control is active The charger only operates when its remote on/off input is active. Most commonly, this is done with the remote connector with a wire link between the L and H terminals. Remote on/off connector with wire loop There are two more ways to activate the remote on/off input; see Remote on/off wiring [8] for the wiring details: ON when the L terminal is pulled to battery minus or ground (ON switch level ON when the H terminal is pulled to battery plus (ON switch level > 3V) General remote on/off terminal check 1.

Check that the charger is not being turned off remotely by an external control (see the note below). 2. Check that the remote terminal connector has been plugged in all the way. 3. Check that the wire link, or the remote control wires, are making good electrical contact. In installations where an external device (such as a switch, relay or BMS) controls the remote on/off, the wire loop is not used. Instead, one or two wires connect the remote terminal to the external device. In that case, check that device and its wiring rather than the wire loop. If in doubt whether an external device is turning the charger off, temporarily place a wire link between the L and H terminals to rule this out.

Remove the link and restore the original wiring afterwards. 7.2.2. The charger is disabled Check the VictronConnect app to make sure the charger has been enabled. VictronConnect enable/disable charger setting 7.2.3. Input voltage lock-out is active Charging is disabled because the input voltage is below the configured lock-out level. Charging resumes automatically when the input voltage rises above the restart level. The input voltage lock-out is a protective feature that prevents the from draining the starter battery. If the message appears, the question is whether the lock-out is doing its job or whether it is triggering when it should not. The input voltage really is low.

The engine is off, the starter battery is discharged, or the alternator is not charging. Measure the input voltage at the charger's input terminals, or read it in the VictronConnect app. Charge the starter battery or run the engine. The lock-out and restart levels are set too high for the system. A smart alternator can operate at a low voltage for extended periods, tripping the lock-out although the engine is running. Compare the configured levels with the actual alternator voltage range; see Automatic engine shutdown detection [10] . Voltage drop over the input cable trips the lock-out at full charge current, even though the alternator voltage is fine.

Check the input cable cross-section and connections, and take the voltage drop into account when choosing the lock-out level; see the calculation example in Engine shutdown detection setup with VictronConnect [11] . The default lock-out and restart levels differ between charger mode and power supply mode. In power supply mode, the input voltage lock-out determines when the output is active. Page 18 Troubleshooting & Support