3 Functions of Devices in DVP-PM 3.12 Special Registers for Manual Mode Settings Below are the types and functions of special registers (special D) for motion modes. See the next section for more details on the functions. You can set the parameters according to explanations of each register and also know more about the system information by these registers.
DVP-PM Application Manual 3-57 Special D X axis Y axis Z axis A axis Content Range Default HW*1 LW*1 HW LW HW LW HW LW D1816 D1896 D1976 D2056 Parameter setting b0 ~ b15 H0 D1819 D1818 D1899 D1898 D1979 D1978 D2059 D2058 Pulses per revolution (PPR) of motor 1 ~ +2,147,483,647 PLS/REV K2,000 D1821 D1820 D1901 D1900 D1981 D1980 D2061 D2060 Displacement per relolution (DPR) of motor 1 ~ +2,147,483,647 *2 K1,000 D1823 D1822 D1903 D1902 D1983 D1982 D2063 D2062 Maximum speed 0 ~ +2,147,483,647 *3 K500,00 0 D1825 D1824 D1905 D1904 D1985 D1984 D2065 D2064 Bias speed: V BIAS 0 ~ +2,147,483,647 *3 K0 D1827 D1826 D1907 D1906 D1987 D1986 D2067 D2066 JOG speed:
V JOG 0 ~ +2,147,483,647 *3 K5,000 D1829 D1828 D1909 D1908 D1989 D1988 D2069 D2068 Zero return speed: V RT 0 ~ +2,147,483,647 *3 K50,000 D1831 D1830 D1911 D1910 D1991 D1990 D2071 D2070 Zero return deceleration speed: V CR 0 ~ +2,147,483,647 *3 K1,000 D1832 D1912 D1992 D2072 Number of PG0 signals: N 0 ~ +32,767 PLS K0 D1833 D1913 D1993 D2073 Number of pulses for zero return: P -32,768 ~ +32,767 PLS K0 D1835 D1834 D1915 D1914 D1995 D1994 D2075 D2074 Definition of zero point: HP 0 ~ ±999,999 *2 K0 D1836 D1916 D1996 D2076 Acceleration time: T ACC 10 ~ +32,767 ms K100 D1837 D1917 D1997 D2077 Deceleration time:
T DEC 10 ~ +32,767 ms K100 D1839 D1838 D1919 D1918 D1999 D1998 D2079 D2078 Target position (I): P(I) -2,147,483,648 ~ +2,147,483,647 *2 K0 D1841 D1840 D1921 D1920 D2001 D2000 D2081 D2080 Operation speed (I): V(I) 0 ~ +2,147,483,647 *2 K1,000 D1843 D1842 D1923 D1922 D2003 D2002 D2083 D2082 Target position (II): P(II) -2,147,483,648 ~ +2,147,483,647 *2 K0 D1845 D1844 D1925 D1924 D2005 D2004 D2085 D2084 Operation speed (II): V(II) 0 ~ +2,147,483,647 *2 K2,000 D1846 D1926 D2006 D2086 Operation commands b0 ~ b15 H0 D1847 D1927 D2007 D2087 Work modes b0 ~ b15 H0 D1849 D1848 D1929 D1928 D2009 D2008 D2089 D2088 Current position:
CP (pulse) -2,147,483,648 ~ +2,147,483,647 *2 K0 D1851 D1850 D1931 D1930 D2011 D2010 D2091 D2090 Current speed: CS (pulse) 0 ~ +2,147,483,647 PPS K0 D1853 D1852 D1933 D1932 D2013 D2012 D2093 D2092 Current position: CP (unit *3 ) -2,147,483,648 ~ +2,147,483,647 *2 K0 D1855 D1854 D1935 D1934 D2015 D2014 D2095 D2094 Current speed: CS (unit *3) 0 ~ +2,147,483,647 PPS K0 D1856 D1936 D2016 D2096 Execution status b0 ~ b15 H0 D1857 D1937 D2017 D2097 Error code See the error code table H0