Mitsubishi — 3.12 Special Registers for Manual Mode Settings

3 Functions of Devices in DVP-PM *1 : HW: High word; LW: Low word *2 : Units available: um/rev, m deg/rev and 10 -4 inch/rev. *3 :

The unit setting follows the settings of b0 and b1 of D1816, D1896 and D1976 (Parameter setting) DVP-PM Application Manual 3-58 Special D X axis Y axis Z axis A axis Content Range Default HW*1 LW*1 HW LW HW LW HW LW D1858 D1938 D2018 D2098 Electronic gear ratio (numerator) 1 ~ +32,767 K1 D1859 D1939 D2019 D2099 Electronic gear ratio (denominator) 1 ~ +32,767 K1 D1861 D1860 D1941 D1940 D2021 D2020 D2101 D2100 MPG input frequency Pulse frequency by MPG input K0 D1863 D1862 D1943 D1942 D2023 D2022 D2103 D2102 Number of accumulated MPG input pulses Number of input pulses from MPG K0 D1864 D1944 D2024 D2104 Response time of MPG input Response time of MPG input K5 D1865 Stop mode (OX0-99) Depending on the demannd K0 D1867 D1866 D1947 D1946 D2027 D2026 D2107 D2106 Coordinate of electrical zero point Depending on the demand K0 D1868 Number of OX subroutine Depending on the demand K0 D1869 Error step of OX subroutine Depending on the demand K0 D1872 Enabling Y output when OX is ready High byte:

K1; low byte: designating start No. of Y output Depending on the demand K0 D1873 Enabling Y output when OX executes M-code High byte: K1; low byte: designating start No. of Y output Depending on the demand K0 D1874 No. of input point X for clearing OX M-code status Depending on the demand K0 D1875 D1955 Enable external input (ZRN, MPG, JOG-, JOG+) Depending on the demand K0