3 Functions of Devices in DVP-PM 3.12.1 Functions of Special Registers for Manual Mode Settings See the tables below for the explanations of b0 ~ b15. ѓ b0 and b1 of D1816 (D1896, D1976, D2056): setting of unit y Position data: zero point position (HP), target position (I) (P(I)), target position (II) (P(II), current position (CP). y Speed data: maximum speed (V MAX ), bias speed (V BIAS ), JOG speed (V JOG ), zero return speed (V RT ), zero return deceleration speed (V CR ), operation speed (I) (V(I)), operation speed (II) (V(II)). y Example 1: b[1:0] = 00: Motor unit @ unit of position: pulse; unit of speed: pulse/sec (PPS) Assume: target position P(I):
10,000 (pulse); operation speed V(I): 10K (PPS) Explanation: When the positioning controller sends out 10,000 pulses (frequency at 10K PPS), the target position can be achieved. The displacement moved by every pulse is calculated by users according to the parameter of connected devices. y Example 2: b[1:0] = 01: Machine unit @ unit of position: um; unit of speed: cm/min Assume: D1818 (D1898/D1978) = 1,000 (Pulse/REV), D1820 (D1900/D1980) = 100 (um/REV), target position P(I) = 10,000 (um), and operation speed V(I) = 6 (cm/min). Solve the number of pulses and the frequency required by pulse instruction of the positioning controller. Solution: 1.
pulses of number Total pulses of Number Revolution Revolution Distance P(I) Distance Total Ч Ч = 4 4 4 3 4 4 4 2 1 43 42 1 A 1 B A: Pulses per revolution (PPR) of motor; B: Displacement per relolution (DPR) of motor DVP-PM Application Manual 3-59 X axis Y axis Z axis A axis Parameter Setting HW LW HW LW HW LW HW LW D1816 D1896 D1976 D2056 b1 b0 Unit Explanation 0 0 Motor Unit: pulse 0 1 Machine Unit: length, angle 1 0 Combined Unit for position: length, angle (machine) Unit for speed: pulse (motor) 1 1 Motor Unit Combined unit Machine Unit pulse um Position pulse m deg pulse 10-4inch pulse/sec cm/min Speed pulse/sec 10deg/min pulse/sec inch/min