Mitsubishi — 3.12.1 Functions of Special Registers for Manual Mode Settings

3 Functions of Devices in DVP-PM zero return deceleration speed V CR . When the falling edge of DOG signal is triggered, the motor will stop according to either PG0 signals (N) or pulse signals (P), of which is finished first. 2. If the specified N or P is too small, when the falling edge of DOG signal is triggered, the motor will stop immediately after the specified PG0 signals (N) or the specified pulse signals (P) of which is finished first, even if the zero return deceleration speed is not yet reached.. 3. If N and P are both set as “0”, the motor will stop immediately when the falling-edge of DOG signal is triggered.

Speed (PPS) Away from DOG signal DOG signal detected V CR V CR Zero return direction Number of pulses (P) in zero return Number of P 0 signals in zero return G DOG DOG signal falling edge triggered y b[9:10] = 11: overwrite mode; DOG signal rising-edge triggered 1. Zero return: The motor operates at zero return speed V RT . When it encounters DOG signal, it will decelerate to zero return deceleration speed V CR . At the same time, rising edge of DOG signal is triggered to enable the specified PG0 signals (N) and the specified pulse signals (P). The motor will stop according to either PG0 signals (N) or pulse signals (P), of which is finished first. 2.

If the specified N or P is too small, when the rising edge of DOG signal is triggered, the motor will stop immediately accoding to either PG0 signals (N) or pulse signals (P), of which is finished first. 3. If N and P are both set as “0”, the motor will stop immediately when the rising-edge of DOG signal is triggered Speed (PPS) Away from DOG signal DOG signal detected V Zero return speed Number of pulses (P) in zero return Number of P 0 signals (N) in zero return G DOG DOG signal rising-edge triggered DVP-PM Application Manual 3-63 V CR