3 Functions of Devices in DVP-PM 1. V BIAS is the start speed for pulse output. Range: 0 ~ +2,147,483,647; the unit is set by b0 and b1 of D1816 (D1896, D1976, D2056). 2. V BIAS should be specified within the valid bias speed range of motion instructions: 0 ~ 500kPPS. If the value is bigger than 500k, the output will be set as 500k; if the value is smaller than 0, the output will be set as 0. 3. If you apply a step drive system, please pay attention to the resonance frequency of the step motor. Set the bias speed higher than the resonance frequency for a safe startup. 2. V JOG should be specified within the valid speed range of motion instructions: 10 ~ 500kPPS. If the value is bigger 1.
Range: 0 ~ +2,147,483,647; the unit is set by b0 and b1 of D1816 (D1896, D1976, D2056). than 500k, the output will be set as 500k; if the value is smaller than 10, the output will be set as 10. 3. Setup range limitation: V MAX > V JOG > V BIAS . If V JOG > V MAX , set value of V JOG will be same as V MAX . If V JOG BIAS , set value of V JOG will be same as V BIAS . 4. V JOG cannot be modified during the execution. Speed V MAX V JOG V BIAS T A T D 1. V RT is the speed for returning to mechanical zero point. Range: 0 ~ +2,147,483,647; the unit is set by b0 and b1 of D1816 (D1896, D1976, D2056). 2. V RT should be specified within the valid speed range of motion instructions: 10 ~ 500kPPS.
If the value is bigger than 500k, the output will be set as 500k; if the value is smaller than 10, the output will be set as 10. 3. Setup range limitation: V MAX > V RT > V BIAS 4. V RT cannot be modified during the execution. DVP-PM Application Manual 3-65 X axis Y axis Z axis A axis Bias Speed (V ) BIAS HW LW HW LW HW LW HW LW D1825 D1824 D1905 D1904 D1985 D1984 D2065 D2064 X axis Y axis Z axis A axis JOG Speed (V ) JOG HW LW HW LW HW LW HW LW D1827 D1826 D1907 D1906 D1987 D1986 D2067 D2066 X axis Y axis Z axis A axis Zero Return Speed V RT HW LW HW LW HW LW HW LW D1829 D1828 D1909 D1908 D1989 D1988 D2069 D2068