Mitsubishi — 3.12.1 Functions of Special Registers for Manual Mode Settings

3 Functions of Devices in DVP-PM 1. Range: 0 ~ +2,147,483,647; the unit is set by b0 and b1 of D1816 (D1896, D1976, D2056). 2. V CR should be specified within the valid speed range of motion instructions: 10 ~ 500kPPS. If the value is bigger 3. When zero return is executed, the motor will operate at zero return speed V RT . When DOG signal is triggered, the than 500k, the output will be set as 500k; if the value is smaller than 10, the output will be set as 10. motor will decelerate to zero return deceleration speed V CR . 4. To perform precise positioning result at zero point, we suggest you set up V CR in low speed. 5. V CR cannot be modified during the execution. 1. Range:

-32,768 ~ 32,767 (pulse). Positive values indicate the number of positive PG0 signals (N). Negative 2. For details about the reference signals for zero return (N, P), please refer to explanations of b9, 10 (zero return values indicate the number of negative PG0 signals (N). mode) of D1816 (D1896, D1976, D2056). 1. Range: -32,768 ~ 32,767 (pulse). Positive values indicate the number of positive zero return pulses (P). Negative 2. For details about the reference signals for zero return (N, P), please refer to explanations of b9, 10 (zero return values indicate the number of negative sero return pulses (P). mode) of D1816 (D1896, D1976, D2056) 1. Range:

0 ~ ±999,999; the unit is set by b0 and b1 of D1816 (D1896, D1976). 2. After zero return is completed, current position (CP) will be updated with zero point (HP). 1. T ACC is the time required from bias speed V BIAS (D1824, D1904, D1984, D2064) to maximum speed V MAX (D1822, D1902, D1982, D2062). 2. If the value is smaller than 10ms, the output will be set as 10ms; if the value is biggler than 32767 ms, the output will be set as 32,767 ms. 3. If you need a complete S curve, please set the operation speed ( V) as maximum speed V MAX .

DVP-PM Application Manual 3-66 X axis Y axis Z axis A axis Zero Return Deceleration Speed V CR HW LW HW LW HW LW HW LW D1831 D1830 D1911 D1910 D1991 D1990 D2071 D2070 X axis Y axis Z axis A axis Number of Zero Point Signals (PG0) (N) HW LW HW LW HW LW HW LW D1832 D1912 D1992 D2072 X axis Y axis Z axis A axis Number of Pulses for Zero Return (P) HW LW HW LW HW LW HW LW D1833 D1913 D1993 D2073 X axis Y axis Z axis A axis Definition of Zero Point (HP) HW LW HW LW HW LW HW LW D1835 D1834 D1915 D1914 D1995 D1994 D2075 D2074 X axis Y axis Z axis A axis Acceleration Time T ACC HW LW HW LW HW LW HW LW D1836 D1916 D1996 D2076