Mitsubishi — 3.12.1 Functions of Special Registers for Manual Mode Settings

3 Functions of Devices in DVP-PM 1. T DEC is the time required from maximum speed V MAX (D1822, D1902, D1982, D2062) to bias speed V BIAS (D1824 2. If the value is smaller than 10ms, the output will be set as 10ms; if the value is biggler than 32767 ms, the output D1904, D1996, D2064). will be set as 32,767 ms. 3. If you need a complete S curve, please set the operation speed ( V) as maximum speed V MAX . 1. Range: -2,147,483,648 ~ +2,147,483,647; the unit is set by b0 and b1 of D1816 (D1896, D1976). 2. Attribute of target position P(I): ♦ Absolute coordinate:

b12 of D1816 (D1896, D1976, D2056) = 0 Absolute coordinate is the coordinate starting from “0.” When the target position P(I) > current position (D1848, D1928, D2008, D2088), the motor will conduct forward running. When the target position P(I) current position, the motor will conduct reverse running. ♦ Relative coordinate: b12 of D1816 (D1896, D1976, D2056) = 1 Relative coordinate is the relative displacement moved from current position (D1848, D1928, D2008, D2088). When the relative coordinate is a positive value, the motor will conduct forward running. When the relative coordinate is a negative value, the motor will conduct reverse running. 3.

The multiplication of position data P(I) varies according to the settings of b2 and b3 in D1816 (D1896, D1976, D2056). 1. Range: 0 ~ +2,147,483,647; the unit is set by b0 and b1 of D1816 (D1896, D1976, D2056). 2. V(I) should be specified within the valid speed range of motion instructions: 10 ~ 500kPPS. If the value is bigger than 500k, the output will be set as 500k; if the value is smaller than 10, the output will be set as 10. 3. Setup range limitation: V MAX > V(I) > V BIAS . 4. When b4 of D1846 (D1926, D2006, D2086) = 1, which enables variable speed operation, the operation speed V(I) can be modified during operation.

When the sign of V(I) is “+”, the motor will conduct forward running; when the sign of V(I) is “-“, the motor will conduct reverse running. 1. Range: -2,147,483,648 ~ +2,147,483,647; the unit is set by b0 and b1 of D1816 (D1896, D1976, D2056).

DVP-PM Application Manual 3-67 X axis Y axis Z axis A axis Deceleration Time T DEC HW LW HW LW HW LW HW LW D1837 D1917 D1997 D2077 X axis Y axis Z axis A axis Target Position (I) (P(I)) HW LW HW LW HW LW HW LW D1839 D1838 D1919 D1918 D1999 D1998 D2079 D2078 X axis Y axis Z axis A axis Operation Speed (I) (V(I)) HW LW HW LW HW LW HW LW D1841 D1840 D1921 D1920 D2001 D2000 D2081 D2080 X axis Y axis Z axis A axis Target Position (II) (P(II)) HW LW HW LW HW LW HW LW D1843 D1842 D1923 D1922 D2003 D2002 D2083 D2082