Mitsubishi — 3.12.1 Functions of Special Registers for Manual Mode Settings

3 Functions of Devices in DVP-PM 2. Attribute of target position P(II): ♦ Absolute coordinate: b12 of D1816 (D1896, D1976, D2056) = 0 Absolute coordinate is the coordinate starting from “0.” When the target position P(II) > current position (D1848, D1928, D2008, D2088), the motor will conduct forward running. When the target position P(II) current position, the motor will conduct reverse running. ♦ Relative coordinate: b12 of D1816 (D1896, D1976, D2056) = 1 Relative coordinate is the relative displacement moved from current position (D1848, D1928, D2008, D2088). When the relative coordinate is a positive value, the motor will conduct forward running.

When the relative coordinate is a negative value, the motor will conduct reverse running.. 3. The multiplication of position data P(II) varies according to the settings of b2 and b3 in D1816 (D1896, D1976, D2056). 1. Range: 0 ~ +2,147,483,647; the unit is set by b0 and b1 of D1816 (D1896, D1976, D2056). 2. V(I) should be specified within the valid speed range of motion instructions: 10 ~ 500kPPS. If the value is bigger than 500k, the output will be set as 500k; if the value is smaller than 10, the output will be set as 10. 3. Setup range limitation: V MAX > V(II) > V BIAS . 1. b0 of D1846 (D1926, D2006, D2086):

STOP ♦ When b0 is rising edge triggered (0→1), the positioning controller decelerate to stop. ♦ The function is the same as the external STOP input signal. The positioning controller will decelerate to stop in both situations.. 2. b1 of D1846 (D1926, D2006, D2086): START ♦ When b1 is rising edge triggered (0→1), the positioning controller will operates according to operation conmmands set in D1846 (D1926, D2006, D2086). 3. b2 of D1846 (D1926, D2006, D2086): enabling JOG+ ♦ b[2] = 1:

JOG+ sends out forward pulses (CW) ♦ When PWM mode is enabled (Parameter Setting, D1816/D1896/D1976/D2056, b[6] = 1), and the operation command “JOG+ operation” is enabled (b[2] = 1), PWM will be executed on Y0~Y3. 4. b3 of D1846 (D1926, D2006, D2086): enabling JOG- ♦ b[3] = 1: JOG- sends out reverse pulses (CCW) 5. b4 of D1846 (D1926, D2006, D2086): variable speed operation ♦ When b[4] = 1 and operation is started (START terminal is ON), DVP-PM will start to send out pulses for performing variable speed operation on positioning controller. ♦ The operation speed will be stable after the speed is accelerated from V BIAS to the expected V(I).

When DVP-PM Application Manual 3-68 X axis Y axis Z axis A axis Operation Speed (II) (V(II)) HW LW HW LW HW LW HW LW D1845 D1844 D1925 D1924 D2005 D2004 D2085 D2084 X axis Y axis Z axis A axis Operation Commands HW LW HW LW HW LW HW LW D1846 D1926 D2006 D2086